Loading checklist…
Where a road or footpath crosses a watercourse, to maintain the water flow, a pipe, box, known as a culvert will be required. A pipe or box less than 600mm in diameter or height shall be designed in accordance with the Draining surface water run-off section. A pipe or box 600mm or greater in diameter or height shall be known as a structure.
Bridges with a distance between supports of 600mm or greater, and walls, known as retaining walls, supporting the roads and footpaths of 600mm or greater in height shall be known as a structure.
All structures shall be designed in accordance with our guidelines for structures.
Structures supporting roads or footpaths may be designed by the County Council.
A road or footpath in a legal agreement with us shall include the supporting structures and all its parts.
A wall supporting soil and located up to 3.65m from a public road or footpath with a height greater than 1.35m must be approved by us.
Some headwalls and parapets may be built or clad with brick. When building brickwork above completed concrete or stonework, precautions should be in place to prevent mortar or debris from falling into the open expansion joints
Exposed joints shall be treated in the following ways:
Facing brickwork shall be securely bonded to the backing bricks or concrete using approved anchor ties as needed and should not be built more than 600mm ahead of the backing bricks or concrete at any time.